18 years of successful growth

Human 3-oxo-5-alpha-steroid 4-dehydrogenase 1(SRD5A1) ELISA kit

Product Details

Target Name steroid-5-alpha-reductase, alpha polypeptide 1 (3-oxo-5 alpha-steroid delta 4-dehydrogenase alpha 1)
Alternative Names 3 oxo 5 alpha steroid 4 dehydrogenase 1 ELISA Kit; 3 oxo 5 alpha steroid delta 4 dehydrogenase alpha 1 ELISA Kit; 3-oxo-5 alpha-steroid delta 4-dehydrogenase alpha 1,5-alpha reductase ELISA Kit; 3-oxo-5-alpha-steroid 4-dehydrogenase 1 ELISA Kit; 5 alpha reductase ELISA Kit; S5A1_HUMAN ELISA Kit; S5AR 1 ELISA Kit; S5AR ELISA Kit; SR type 1 ELISA Kit; SRD5A 1 ELISA Kit; Srd5a1 ELISA Kit; Steroid 5 alpha reductase 1 ELISA Kit; Steroid 5 alpha reductase alpha polypeptide 1 (3 oxo 5 alpha steroid delta 4 dehydrogenase alpha 1) ELISA Kit; Steroid 5 alpha reductase alpha polypeptide 1 ELISA Kit; Steroid 5 alpha reductase type I ELISA Kit; Steroid 5-alpha-reductase 1 ELISA Kit
Abbreviation SRD5A1
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates, cell lysates
Detection Range 0.156 ng/mL-10 ng/mL
Sensitivity 0.039 ng/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Neuroscience
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human SRD5A1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 95  
Range % 90-102  
1:2 Average % 90  
Range % 84-95  
1:4 Average % 101  
Range % 95-106  
1:8 Average % 98  
Range % 92-104  
Recovery
The recovery of human SRD5A1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 89 85-93  
EDTA plasma (n=4) 92 87-96  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
ng/ml OD1 OD2 Average Corrected  
10 2.017 2.063 2.040 1.795  
5 1.499 1.472 1.486 1.241  
2.5 1.004 1.064 1.034 0.789  
1.25 0.705 0.742 0.724 0.479  
0.625 0.501 0.536 0.519 0.274  
0.312 0.412 0.438 0.425 0.180  
0.156 0.347 0.361 0.354 0.109  
0 0.241 0.249 0.245    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 5-7 working days
Download X-Ray Brochures