18 years of successful growth

Human 3-oxo-5-alpha-steroid 4-dehydrogenase 2(SRD5A2) ELISA kit

Product Details

Target Name steroid-5-alpha-reductase, alpha polypeptide 2 (3-oxo-5 alpha-steroid delta 4-dehydrogenase alpha 2)
Alternative Names 3 oxo 5 alpha steroid 4 dehydrogenase 2 ELISA Kit; 3-oxo-5-alpha-steroid 4-dehydrogenase 2 ELISA Kit; 5 alpha SR2 ELISA Kit; 5 alpha-SR2 ELISA Kit; 5ART2 ELISA Kit; e II 5 alpha reductase ELISA Kit; EC ELISA Kit; MGC138457 ELISA Kit; Micropenis, included ELISA Kit; S5A2_HUMAN ELISA Kit; S5AR 2 ELISA Kit; SR type 2 ELISA Kit; SRD5A2 ELISA Kit; Steroid 5 alpha reductase 2 ELISA Kit; Steroid 5-alpha-reductase 2 ELISA Kit; Steroid-5-alpha-reductase, alpha polypeptide 2 (3-oxo-5 alpha-steroid delta 4-dehydrogenase alpha 2) ELISA Kit; Type II 5-alpha reductase ELISA Kit
Abbreviation SRD5A2
Uniprot No. P31213
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates
Detection Range 12 pg/mL-2400 pg/mL
Sensitivity 6 pg/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Signal Transduction
Assay Principle quantitative
Measurement Competitive
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human SRD5A2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 88  
Range % 85-93  
1:2 Average % 91  
Range % 87-98  
1:4 Average % 94  
Range % 89-99  
1:8 Average % 94  
Range % 82-97  
Recovery
The recovery of human SRD5A2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 96 90-102  
EDTA plasma (n=4) 97 91-104  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/ml OD1 OD2 Average    
0 2.053 2.137 2.095    
12 1.498 1.488 1.493    
48 1.086 1.052 1.069    
192 0.591 0.620 0.606    
600 0.261 0.276 0.269    
2400 0.114 0.115 0.115    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 5-7 working days
Download X-Ray Brochures