Human Acetyl-CoA carboxylase 1(ACACA) ELISA kit

Product Details

Target Name acetyl-Coenzyme A carboxylase alpha
Alternative Names ACAC ELISA Kit; ACACA ELISA Kit; ACACA_HUMAN ELISA Kit; ACACB ELISA Kit; ACC alpha ELISA Kit; ACC ELISA Kit; ACC beta ELISA Kit; ACC-alpha ELISA Kit; ACC1 ELISA Kit; ACC2 ELISA Kit; ACCA ELISA Kit; ACCB ELISA Kit; Acetyl CoA carboxylase 1 ELISA Kit; Acetyl CoA carboxylase 2 ELISA Kit; Acetyl CoA carboxylase alpha ELISA Kit; Acetyl CoA carboxylase beta ELISA Kit; Acetyl Coenzyme A carboxylase alpha ELISA Kit; Acetyl Coenzyme A carboxylase beta ELISA Kit; Biotin carboxylase ELISA Kit; COA1 ELISA Kit; COA2 ELISA Kit; HACC275 ELISA Kit; OTTHUMP00000164069 ELISA Kit; OTTHUMP00000164070 ELISA Kit; OTTHUMP00000164076 ELISA Kit; OTTHUMP00000240532 ELISA Kit
Abbreviation ACACA
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates, cell lysates
Detection Range 9.38 pg/mL-600 pg/mL
Sensitivity 2.34 pg/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Metabolism
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%        
Three samples of known concentration were tested twenty times on one plate to assess.    
Inter-assay Precision (Precision between assays): CV%        
Three samples of known concentration were tested in twenty assays to assess.      
               
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human ACACA in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.  
  Sample Serum(n=4)    
1:5 Average % 98    
Range % 96-102    
1:10 Average % 107    
Range % 103-114    
1:20 Average % 94    
Range % 90-98    
1:40 Average % 88    
Range % 86-95    
Recovery
The recovery of human ACACA spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.  
 
Sample Type Average % Recovery Range    
Serum (n=5) 105 99-108    
EDTA plasma (n=4) 94 90-98    
               
               
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.  
 
pg/ml OD1 OD2 Average Corrected    
600 2.169 2.202 2.186 2.004    
300 1.702 1.814 1.758 1.576    
150 1.202 1.254 1.228 1.046    
75 0.711 0.747 0.729 0.547    
37.5 0.503 0.506 0.505 0.323    
18.75 0.284 0.298 0.291 0.109    
9.38 0.236 0.249 0.243 0.061    
0 0.174 0.189 0.182      
    .          
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 5-7 working days