18 years of successful growth

Human Adipose Triglyceride Lipase,ATGL ELISA kit

Product Details

Target Name patatin-like phospholipase domain containing 2
Alternative Names 1110001C14Rik ELISA Kit; Adipose triglyceride lipase ELISA Kit; ATGL ELISA Kit; ATGL DESNUTRIN ELISA Kit; Calcium independent phospholipase A2 ELISA Kit; Calcium-independent phospholipase A2 ELISA Kit; Desnutrin ELISA Kit; EC 3.1.1.3 ELISA Kit; FP17548 ELISA Kit; IPLA2 zeta ELISA Kit; IPLA2-zeta ELISA Kit; Mutant patatin like phospholipase domain containing 2 ELISA Kit; Patatin like phospholipase domain containing 2 ELISA Kit; PATATIN LIKE PHOSPHOLIPASE DOMAIN CONTAINING PROTEIN 2 ELISA Kit; Patatin-like phospholipase domain-containing protein 2 ELISA Kit; PEDF R ELISA Kit; PHOSPHOLIPASE A2 CALCIUM INDEPENDENT ZETA ELISA Kit; Pigment epithelium derived factor ELISA Kit; Pigment epithelium-derived factor ELISA Kit; plpl ELISA Kit; plpl2 ELISA Kit; PLPL2_HUMAN ELISA Kit; Pnpla2 ELISA Kit; Transport secretion protein 2 ELISA Kit; Transport secretion protein 2.2 ELISA Kit; Transport-secretion protein 2 ELISA Kit; Triglyceride hydrolase ELISA Kit; TTS 2.2 ELISA Kit; TTS2 ELISA Kit; TTS2.2 ELISA Kit; ZETA ELISA Kit
Abbreviation PNPLA2
Species Homo sapiens (Human)
Sample Types serum, urine, tissue homogenates
Detection Range 6.25 mIU/mL-400 mIU/mL
Sensitivity 1.56 mIU/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Metabolism
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human ATGL in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 88  
Range % 82-95  
1:2 Average % 96  
Range % 90-100  
1:4 Average % 93  
Range % 88-105  
1:8 Average % 95  
Range % 82-110  
Recovery
The recovery of human ATGL spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 95 82-103  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
mIU/ml OD1 OD2 Average Corrected  
400 2.083 1.992 2.038 1.916  
200 1.854 1.796 1.825 1.703  
100 1.529 1.484 1.507 1.385  
50 1.038 0.976 1.007 0.885  
25 0.771 0.709 0.740 0.618  
12.5 0.429 0.395 0.412 0.290  
6.25 0.286 0.269 0.278 0.156  
0 0.124 0.119 0.122    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days
Download X-Ray Brochures