Human C-type mannose receptor 2(MRC2) ELISA kit
Product Details
| Target Name |
mannose receptor, C type 2 |
| Alternative Names |
C-type lectin domain family 13 member E ELISA Kit; C-type mannose receptor 2 ELISA Kit; CD 280 ELISA Kit; CD280 ELISA Kit; CD280 antigen ELISA Kit; CLEC 13E ELISA Kit; CLEC13E ELISA Kit; ENDO 180 ELISA Kit; ENDO180 ELISA Kit; Endocytic receptor (macrophage mannose receptor family) ELISA Kit; Endocytic receptor 180 ELISA Kit; FLJ35911 ELISA Kit; KIAA0709 ELISA Kit; Macrophage mannose receptor 2 ELISA Kit; Mannose receptor C type 2 ELISA Kit; MRC 2 ELISA Kit; MRC2 ELISA Kit; MRC2_HUMAN ELISA Kit; UPAR-associated protein ELISA Kit; UPARAP ELISA Kit; Urokinase plasminogen activator receptor associated protein ELISA Kit; Urokinase receptor associated protein ELISA Kit; Urokinase receptor-associated protein ELISA Kit; Urokinase-type plasminogen activator receptor-associated protein ELISA Kit |
| Abbreviation |
MRC2 |
| Species |
Homo sapiens (Human) |
| Sample Types |
serum, plasma, tissue homogenates, cell lysates |
| Detection Range |
0.156 ng/mL-10 ng/mL |
| Sensitivity |
0.039 ng/mL |
| Assay Time |
1-5h |
| Sample Volume |
50-100ul |
| Detection Wavelength |
450 nm |
| Research Area |
Immunology |
| Assay Principle |
quantitative |
| Measurement |
Sandwich |
| Precision |
| Intra-assay Precision (Precision within an assay): CV% |
| Three samples of known concentration were tested twenty times on one plate to assess. |
|
| Inter-assay Precision (Precision between assays): CV% |
| Three samples of known concentration were tested in twenty assays to assess. |
|
|
| |
|
|
|
|
|
|
|
| Linearity |
| To assess the linearity of the assay, samples were spiked with high concentrations of human MRC2 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| |
Sample |
Serum(n=4) |
|
| 1:1 |
Average % |
85 |
|
| Range % |
80-90 |
|
| 1:2 |
Average % |
94 |
|
| Range % |
88-105 |
|
| 1:4 |
Average % |
99 |
|
| Range % |
90-110 |
|
| 1:8 |
Average % |
94 |
|
| Range % |
80-100 |
|
|
| Recovery |
| The recovery of human MRC2 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
| Sample Type |
Average % Recovery |
Range |
|
| Serum (n=5) |
93 |
80-98 |
|
| EDTA plasma (n=4) |
99 |
92-110 |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Typical Data |
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
| ng/ml |
OD1 |
OD2 |
Average |
Corrected |
|
| 10 |
2.045 |
1.952 |
1.999 |
1.810 |
|
| 5 |
1.612 |
1.706 |
1.659 |
1.470 |
|
| 2.5 |
1.312 |
1.240 |
1.276 |
1.087 |
|
| 1.25 |
0.841 |
0.839 |
0.840 |
0.651 |
|
| 0.625 |
0.650 |
0.605 |
0.628 |
0.439 |
|
| 0.312 |
0.446 |
0.415 |
0.431 |
0.242 |
|
| 0.156 |
0.275 |
0.269 |
0.272 |
0.083 |
|
| 0 |
0.191 |
0.187 |
0.189 |
|
|
|
|
| Storage |
Store at 2-8°C. Please refer to protocol. |
| Lead Time |
5-7 working days |