Human Caspase 1(Casp-1) ELISA Kit

Product Details

Description
The Human Caspase 1 (Casp-1) ELISA Kit is suitable for quantitative detection of Casp-1 in serum, plasma, and tissue homogenates. Samples or standards are added into the microwells and bind to the anti-human Casp-1 antibody immobilized on the microplate. A sandwich is formed by the addition of the biotin-conjugated Casp-1 antibody. The TMB substrate solution is added that reacts with the enzyme-antibody-target complex to elicit a chromogenic reaction. The intensity of the solution color is directly proportional to the concentration of Casp-1 present in the original specimen. This kit has been verified with a wide detection range (12.5 pg/mL-800 pg/mL), high sensitivity, excellent specificity, precision less than 10%, good linearity, high recovery, and good consistency between lots. Refer to the product instructions for more verification details. Casp-1 is synthesized as an inactive zymogen that is recruited and activated by inflammasomes. It plays a crucial role in cell immunity 
Target Name caspase 1, apoptosis-related cysteine peptidase (interleukin 1, beta, convertase)
Alternative Names CASP-1 ELISA Kit; CASP1 ELISA Kit; CASP1_HUMAN ELISA Kit; Caspase 1 ELISA Kit; Caspase-1 subunit p10 ELISA Kit; ICE ELISA Kit; IL-1 beta-converting enzyme ELISA Kit; IL-1BC ELISA Kit; IL1 beta converting enzyme ELISA Kit; IL1B convertase ELISA Kit; Interleukin 1 beta convertase ELISA Kit; Interleukin 1B converting enzyme ELISA Kit; Interleukin-1 beta convertase ELISA Kit; Interleukin-1 beta-converting enzyme ELISA Kit; p45 ELISA Kit
Abbreviation CASP1
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates
Detection Range 12.5 pg/mL-800 pg/mL
Sensitivity 3.1 pg/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Cell Biology
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human Casp-1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 86  
Range % 81-92  
1:2 Average % 101  
Range % 96-105  
1:4 Average % 94  
Range % 89-98  
1:8 Average % 103  
Range % 97-108  
Recovery
The recovery of human Casp-1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 101 97-105  
EDTA plasma (n=4) 92 88-96  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/ml OD1 OD2 Average Corrected  
800 2.112 1.984 2.048 1.920  
400 1.634 1.537 1.586 1.458  
200 1.124 1.085 1.105 0.977  
100 0.718 0.693 0.706 0.578  
50 0.389 0.394 0.392 0.264  
25 0.262 0.274 0.268 0.140  
12.5 0.189 0.182 0.186 0.058  
0 0.128 0.127 0.128    
Materials provided
  • A micro ELISA plate --- The 96-well plate has been pre-coated with an anti-human Casp-1 antibody. This dismountable microplate can be divided into 12 x 8 strip plates.
  • Two vials lyophilized standard ---Dilute a bottle of the standard at dilution series, read the OD values, and then draw a standard curve.
  • One vial Biotin-labeled Casp-1 antibody (100 x concentrate) (120 μl/bottle) ---Act as the detection antibody.
  • One vial HRP-avidin (100 x concentrate) (120 μl/bottle) ---Bind to the detection antibody and react with the TMB substrate to make the solution chromogenic.
  • One vial Biotin-antibody Diluent (15 ml/bottle) ---Dilute the Biotin-antibody.
  • One vial HRP-avidin Diluent (15 ml/bottle) ---Dilute the HRP-avidin solution.
  • One vial Sample Diluent (50 ml/bottle)---Dilute the sample to an appropriate concentration.
  • One vial Wash Buffer (25 x concentrate) (20 ml/bottle) ---Wash away unbound or free substances.
  • One vial TMB Substrate (10 ml/bottle) ---Act as the chromogenic agent. TMB interacts with HRP, eliciting the solution turns blue.
  • One vial Stop Solution (10 ml/bottle) ---Stop the color reaction. The solution color immediately turns from blue to yellow.
  • Four Adhesive Strips (For 96 wells) --- Cover the microplate when incubation.
  • An instruction manual
Materials not provided
  • A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
  • An incubator can provide stable incubation conditions up to 37°C±5°C.
  • Centrifuge
  • Vortex
  • Squirt bottle, manifold dispenser, or automated microplate washer
  • Absorbent paper for blotting the microtiter plate
  • 50-300ul multi-channel micropipette
  • Pipette tips
  • Single-channel micropipette with different ranges
  • 100ml and 500ml graduated cylinders
  • Deionized or distilled water
  • Timer
  • Test tubes for dilution
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days