Human Glutathione peroxidase 3(GPX3) ELISA kit
Product Details
Target Name |
glutathione peroxidase 3 |
Alternative Names |
Extracellular glutathione peroxidase ELISA Kit; Glutathione peroxidase 3 (plasma) ELISA Kit; Glutathione peroxidase 3 ELISA Kit; GPX 3 ELISA Kit; GPx P ELISA Kit; GPx-3 ELISA Kit; GPx-P ELISA Kit; GPX3 ELISA Kit; GPX3_HUMAN ELISA Kit; GPXP ELISA Kit; GSHPx 3 ELISA Kit; GSHPx P ELISA Kit; GSHPx-3 ELISA Kit; GSHPx-P ELISA Kit; Plasma glutathione peroxidase 3 ELISA Kit; Plasma glutathione peroxidase ELISA Kit |
Abbreviation |
GPX3 |
Species |
Homo sapiens (Human) |
Sample Types |
serum, plasma, tissue homogenates |
Detection Range |
15.6 μIU/mL-1000 μIU/mL |
Sensitivity |
3.9 μIU/mL |
Assay Time |
1-5h |
Sample Volume |
50-100ul |
Detection Wavelength |
450 nm |
Research Area |
Cancer |
Assay Principle |
quantitative |
Measurement |
Sandwich |
Precision |
Intra-assay Precision (Precision within an assay): CV% |
Three samples of known concentration were tested twenty times on one plate to assess. |
|
Inter-assay Precision (Precision between assays): CV% |
Three samples of known concentration were tested in twenty assays to assess. |
|
|
|
|
|
|
|
|
|
|
Linearity |
To assess the linearity of the assay, samples were spiked with high concentrations of human GPX3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
|
Sample |
Serum(n=4) |
|
1:1000 |
Average % |
93 |
|
Range % |
89-95 |
|
1:2000 |
Average % |
104 |
|
Range % |
100-107 |
|
1:4000 |
Average % |
92 |
|
Range % |
89-96 |
|
1:8000 |
Average % |
98 |
|
Range % |
95-103 |
|
|
Recovery |
The recovery of human GPX3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
Sample Type |
Average % Recovery |
Range |
|
Serum (n=5) |
95 |
90-98 |
|
EDTA plasma (n=4) |
96 |
94-98 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Typical Data |
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
µIU/ml |
OD1 |
OD2 |
Average |
Corrected |
|
1000 |
2.630 |
2.566 |
2.598 |
2.458 |
|
500 |
2.330 |
2.224 |
2.277 |
2.137 |
|
250 |
1.736 |
1.704 |
1.720 |
1.580 |
|
125 |
1.000 |
1.052 |
1.026 |
0.886 |
|
62.5 |
0.622 |
0.608 |
0.615 |
0.475 |
|
31.25 |
0.351 |
0.369 |
0.360 |
0.220 |
|
15.6 |
0.234 |
0.222 |
0.228 |
0.088 |
|
0 |
0.142 |
0.138 |
0.140 |
|
|
|
|
Storage |
Store at 2-8°C. Please refer to protocol. |
Lead Time |
3-5 working days |