18 years of successful growth

Human Integrin beta-3(ITGB3) ELISA kit

Product Details

Target Name integrin, beta 3 (platelet glycoprotein IIIa, antigen CD61)
Alternative Names BDPLT16 ELISA Kit; BDPLT2 ELISA Kit; CD 61 ELISA Kit; CD61 ELISA Kit; CD61 antigen ELISA Kit; GP3A ELISA Kit; GPIIIa ELISA Kit; GT ELISA Kit; HPA 1 ELISA Kit; HPA 4 ELISA Kit; Integrin beta 3 (platelet glycoprotein IIIa antigen CD61) ELISA Kit; Integrin beta chain beta 3 ELISA Kit; Integrin beta-3 ELISA Kit; ITB3_HUMAN ELISA Kit; ITG B3 ELISA Kit; ITGB 3 ELISA Kit; ITGB3 ELISA Kit; NAIT ELISA Kit; platelet fibrinogen receptor ELISA Kit; Platelet fibrinogen receptor beta subunit ELISA Kit; Platelet fibrinogen receptor, beta subunit ELISA Kit; Platelet glycoprotein IIIa ELISA Kit; Platelet glycoprotein IIIa precursor ELISA Kit; Platelet membrane glycoprotein IIIa ELISA Kit; PTP ELISA Kit
Abbreviation ITGB3
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates, cell lysates
Detection Range 125 pg/mL-8000 pg/mL
Sensitivity 31.25 pg/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Signal Transduction
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human ITGB3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 91  
Range % 86-96  
1:2 Average % 95  
Range % 90-105  
1:4 Average % 103  
Range % 97-108  
1:8 Average % 89  
Range % 85-94  
Recovery
The recovery of human ITGB3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 92 88-97  
EDTA plasma (n=4) 97 90-105  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/ml OD1 OD2 Average Corrected  
8000 2.433 2.579 2.506 2.362  
4000 1.887 1.936 1.912 1.768  
2000 1.406 1.488 1.447 1.303  
1000 0.949 1.015 0.982 0.838  
500 0.635 0.669 0.652 0.508  
250 0.371 0.345 0.358 0.214  
125 0.262 0.247 0.255 0.111  
0 0.140 0.148 0.144    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 5-7 working days
Download X-Ray Brochures