18 years of successful growth

Human Kininogen-1(KNG1) ELISA kit

Product Details

Target Name kininogen 1
Alternative Names Alpha-2-thiol proteinase inhibitor ELISA Kit; BDK ELISA Kit; BK ELISA Kit; Bradykinin ELISA Kit; Bradykinin included ELISA Kit; Fitzgerald factor ELISA Kit; FLAUJEAC FACTOR ELISA Kit; High molecular weight kininogen ELISA Kit; HMWK ELISA Kit; Ile-Ser-Bradykinin ELISA Kit; Kallidin I ELISA Kit; Kallidin II ELISA Kit; KNG ELISA Kit; KNG1 ELISA Kit; KNG1_HUMAN ELISA Kit; Low molecular weight growth-promoting factor ELISA Kit; WILLIAMS FACTOR ELISA Kit; Williams-Fitzgerald-Flaujeac factor ELISA Kit
Abbreviation KNG1
Species Homo sapiens (Human)
Sample Types serum, plasma, cell culture supernates, tissue homogenates
Detection Range 47 ng/mL-3000 ng/mL
Sensitivity 11.75 ng/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Cardiovascular
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%        
Three samples of known concentration were tested twenty times on one plate to assess.    
Inter-assay Precision (Precision between assays): CV%        
Three samples of known concentration were tested in twenty assays to assess.      
               
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human KNG1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.  
  Sample Serum(n=4)    
1:100 Average % 99    
Range % 90-103    
1:200 Average % 105    
Range % 98-109    
1:400 Average % 92    
Range % 83-97    
1:800 Average % 95    
Range % 87-98    
Recovery
The recovery of human KNG1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.  
 
Sample Type Average % Recovery Range    
Serum (n=5) 108 99-112    
EDTA plasma (n=4) 94 86-98    
               
               
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.  
 
ng/ml OD1 OD2 Average Corrected    
3000 2.805 2.673 2.739 2.626    
1500 2.300 2.255 2.278 2.165    
750 1.518 1.482 1.500 1.387    
375 0.766 0.779 0.773 0.660    
187.5 0.396 0.414 0.405 0.292    
94 0.241 0.233 0.237 0.124    
47 0.152 0.158 0.155 0.042    
0 0.114 0.112 0.113      
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 5-7 working days
Download X-Ray Brochures