Human Macrophage scavenger receptor types I and II(MSR1) ELISA kit

Product Details

Target Name macrophage scavenger receptor 1
Alternative Names CD204 ELISA Kit; CD204 antigen ELISA Kit; CD24 ELISA Kit; Macrophage acetylated LDL receptor I and II ELISA Kit; Macrophage scavenger receptor 1 ELISA Kit; Macrophage scavenger receptor type III ELISA Kit; Macrophage scavenger receptor types I and II ELISA Kit; Msr 1 ELISA Kit; MSR1 ELISA Kit; MSRE_HUMAN ELISA Kit; phSR1 ELISA Kit; phSR2 ELISA Kit; SCARA 1 ELISA Kit; SCARA1 ELISA Kit; Scavenger receptor class A member 1 ELISA Kit; Scavenger receptor class A, member 1 ELISA Kit; Scavenger receptor type A ELISA Kit; Scvr ELISA Kit; SR A ELISA Kit; SRA ELISA Kit
Abbreviation MSR1
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates
Detection Range 78 pg/mL-5000 pg/mL
Sensitivity 19.5 pg/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Cardiovascular
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human MSR1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 91  
Range % 86-95  
1:2 Average % 92  
Range % 87-96  
1:4 Average % 88  
Range % 82-94  
1:8 Average % 87  
Range % 82-92  
Recovery
The recovery of human MSR1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 99 95-104  
EDTA plasma (n=4) 86 82-92  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/ml OD1 OD2 Average Corrected  
5000 2.342 2.164 2.253 2.119  
2500 1.676 1.772 1.724 1.590  
1250 1.194 1.153 1.174 1.040  
625 0.764 0.751 0.758 0.624  
312 0.452 0.449 0.451 0.317  
156 0.313 0.301 0.307 0.173  
78 0.222 0.214 0.218 0.084  
0 0.134 0.133 0.134    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 5-7 working days
Download X-Ray Brochures