Human Mu-type opioid receptor(OPRM1) ELISA kit
Product Details
| Target Name |
opioid receptor, mu 1 |
| Alternative Names |
hMOP ELISA Kit; LMOR ELISA Kit; M-OR-1 ELISA Kit; MOP ELISA Kit; MOR ELISA Kit; MOR-1 ELISA Kit; MOR1 ELISA Kit; Mu opiate receptor ELISA Kit; Mu opioid receptor ELISA Kit; Mu-type opioid receptor ELISA Kit; Opioid receptor mu 1 ELISA Kit; OPRM ELISA Kit; OPRM_HUMAN ELISA Kit; OPRM1 ELISA Kit |
| Abbreviation |
OPRM1 |
| Species |
Homo sapiens (Human) |
| Sample Types |
serum, plasma, tissue homogenates, cell lysates |
| Detection Range |
31.25 pg/mL-2000 pg/mL |
| Sensitivity |
7.81 pg/mL |
| Assay Time |
1-5h |
| Sample Volume |
50-100ul |
| Detection Wavelength |
450 nm |
| Research Area |
Neuroscience |
| Assay Principle |
quantitative |
| Measurement |
Sandwich |
| Precision |
| Intra-assay Precision (Precision within an assay): CV% |
| Three samples of known concentration were tested twenty times on one plate to assess. |
|
| Inter-assay Precision (Precision between assays): CV% |
| Three samples of known concentration were tested in twenty assays to assess. |
|
|
| |
|
|
|
|
|
|
|
| Linearity |
| To assess the linearity of the assay, samples were spiked with high concentrations of human OPRM1 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| |
Sample |
Serum(n=4) |
|
| 1:1 |
Average % |
96 |
|
| Range % |
85-101 |
|
| 1:2 |
Average % |
95 |
|
| Range % |
89-99 |
|
| 1:4 |
Average % |
93 |
|
| Range % |
88-103 |
|
| 1:8 |
Average % |
96 |
|
| Range % |
83-105 |
|
|
| Recovery |
| The recovery of human OPRM1 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
| Sample Type |
Average % Recovery |
Range |
|
| Serum (n=5) |
92 |
85-99 |
|
| EDTA plasma (n=4) |
98 |
95-106 |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Typical Data |
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
| pg/ml |
OD1 |
OD2 |
Average |
Corrected |
|
| 2000 |
2.123 |
2.091 |
2.107 |
2.003 |
|
| 1000 |
1.869 |
1.853 |
1.861 |
1.757 |
|
| 500 |
1.541 |
1.528 |
1.535 |
1.431 |
|
| 250 |
1.112 |
1.096 |
1.104 |
1.000 |
|
| 125 |
0.708 |
0.695 |
0.702 |
0.598 |
|
| 62.5 |
0.500 |
0.487 |
0.494 |
0.390 |
|
| 31.25 |
0.289 |
0.279 |
0.284 |
0.180 |
|
| 0 |
0.104 |
0.103 |
0.104 |
|
|
|
|
| Storage |
Store at 2-8°C. Please refer to protocol. |
| Lead Time |
7-14 working days |