Human Myelin-oligodendrocyte glycoprotein(MOG) ELISA kit
Product Details
| Target Name |
myelin oligodendrocyte glycoprotein |
| Alternative Names |
BTN6 ELISA Kit; BTNL11 ELISA Kit; MGC26137 ELISA Kit; MOG alpha 5 ELISA Kit; MOG alpha 6 ELISA Kit; MOG AluA ELISA Kit; MOG AluB ELISA Kit; MOG ELISA Kit; MOG Ig AluB ELISA Kit; MOG_HUMAN ELISA Kit; MOGIG2 ELISA Kit; Myelin oligodendrocyte glycoprotein ELISA Kit; Myelin-oligodendrocyte glycoprotein ELISA Kit; NRCLP7 ELISA Kit |
| Abbreviation |
MOG |
| Species |
Homo sapiens (Human) |
| Sample Types |
serum, plasma, tissue homogenates |
| Detection Range |
15.6 pg/mL-1000 pg/mL |
| Sensitivity |
3.9 pg/mL |
| Assay Time |
1-5h |
| Sample Volume |
50-100ul |
| Detection Wavelength |
450 nm |
| Research Area |
Neuroscience |
| Assay Principle |
quantitative |
| Measurement |
Sandwich |
| Precision |
| Intra-assay Precision (Precision within an assay): CV% |
| Three samples of known concentration were tested twenty times on one plate to assess. |
|
| Inter-assay Precision (Precision between assays): CV% |
| Three samples of known concentration were tested in twenty assays to assess. |
|
|
| |
|
|
|
|
|
|
|
| Linearity |
| To assess the linearity of the assay, samples were spiked with high concentrations of human MOG in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
| |
Sample |
Serum(n=4) |
|
| 1:1 |
Average % |
96 |
|
| Range % |
85-103 |
|
| 1:2 |
Average % |
88 |
|
| Range % |
81-99 |
|
| 1:4 |
Average % |
95 |
|
| Range % |
92-107 |
|
| 1:8 |
Average % |
93 |
|
| Range % |
86-100 |
|
|
| Recovery |
| The recovery of human MOG spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
| Sample Type |
Average % Recovery |
Range |
|
| Serum (n=5) |
98 |
93-102 |
|
| EDTA plasma (n=4) |
96 |
91-100 |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Typical Data |
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
| pg/ml |
OD1 |
OD2 |
Average |
Corrected |
|
| 1000 |
2.523 |
2.464 |
2.494 |
2.357 |
|
| 500 |
1.822 |
1.795 |
1.809 |
1.672 |
|
| 250 |
0.986 |
1.025 |
1.006 |
0.869 |
|
| 125 |
0.608 |
0.582 |
0.595 |
0.458 |
|
| 62.5 |
0.412 |
0.403 |
0.408 |
0.271 |
|
| 31.2 |
0.290 |
0.295 |
0.293 |
0.156 |
|
| 15.6 |
0.211 |
0.204 |
0.208 |
0.071 |
|
| 0 |
0.141 |
0.133 |
0.137 |
|
|
|
|
| Storage |
Store at 2-8°C. Please refer to protocol. |
| Lead Time |
5-7 working days |