18 years of successful growth

Human Myosin-11(MYH11) ELISA kit

Product Details

Target Name myosin, heavy chain 11, smooth muscle
Alternative Names AAT4 ELISA Kit; DKFZp686D10126 ELISA Kit; DKFZp686D19237 ELISA Kit; FAA4 ELISA Kit; FLJ35232 ELISA Kit; MGC126726 ELISA Kit; MGC32963 ELISA Kit; MYH 11 ELISA Kit; MYH11 ELISA Kit; MYH11_HUMAN ELISA Kit; Myosin 11 ELISA Kit; Myosin heavy chain 11 ELISA Kit; Myosin heavy chain 11 smooth muscle ELISA Kit; Myosin heavy chain ELISA Kit; Myosin heavy chain smooth muscle isoform ELISA Kit; Myosin heavy polypeptide 11 smooth muscle ELISA Kit; Myosin-11 ELISA Kit; SMHC ELISA Kit; SMMHC ELISA Kit; smooth muscle isoform ELISA Kit; Smooth muscle myosin heavy chain 11 isoform SM2 ELISA Kit; Smooth muscle myosin heavy chain isoform SM2 ELISA Kit
Abbreviation MYH11
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates, cell lysates
Detection Range 25 pg/mL-1600 pg/mL
Sensitivity 6.25 pg/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Signal Transduction
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human MYH11 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 95  
Range % 89-99  
1:2 Average % 102  
Range % 97-105  
1:4 Average % 98  
Range % 92-101  
1:8 Average % 95  
Range % 86-98  
Recovery
The recovery of human MYH11 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 97 94-101  
EDTA plasma (n=4) 88 82-94  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/ml OD1 OD2 Average Corrected  
1600 2.295 2.498 2.397 2.258  
800 1.543 1.442 1.493 1.354  
400 0.891 0.843 0.867 0.728  
200 0.528 0.537 0.533 0.394  
100 0.322 0.335 0.329 0.190  
50 0.255 0.267 0.261 0.122  
25 0.174 0.179 0.177 0.038  
0 0.138 0.139 0.139    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 7-14 working days
Download X-Ray Brochures