18 years of successful growth

Human N-terminal pro-brain natriuretic peptide,NT-proBNP ELISA KIT

Product Details

Description

This Human N-terminal pro-brain natriuretic peptide (NT-proBNP) ELISA Kit is used to quantitatively determine mouse NT-proBNP concentrations in serum, plasma, or tissue homogenates.NT-proBNP is a cardiac hormone secreted by atria and ventricles and released into circulation upon ventricular stretch or ischemia. Congestive heart failure (CHF) is the chief culprit to elevate the levels of NT-proBNP. NT-proBNP is a very good marker of cardiac function and a strong prognostic parameter in patients with coronary heart disease and heart failure. Lucian MURESAN etc. demonstrated that NT-proBNP levels could become a useful ventricular arrhythmia marker for assessing the arrhythmic risk in patients with systemic sclerosis.

This kit employs the quantitative sandwich enzyme immunoassay technique to measure the levels of human NT-proBNP in the sample. Antibody specific for NT-proBNP has been pre-coated onto the microplate. Standards and samples are pipetted into the wells and any NT-proBNP present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated NT-proBNP antibody is added to the wells. After washing, avidin conjugated HRP is added to the wells, forming an antibody-antigen-enzyme-labeled antibody complex. Following a wash to remove any unbound HRP-avidin, the TMB substrate solution is added to the wells, and color develops into blue. The color changes from blue to yellow after the addition of stop solution into the wells. The intensity of the color is in proportion to the amount of NT-proBNP bound in the initial step. The absorbance (OD value) was determined by the microplate reader at the wavelength of 450nm, and the concentration of mouse NT-proBNP was calculated through the standard curve. Each manufactured lot of this ELISA kit is quality tested for criteria such as sensitivity, specificity, precision, linearity, and lot-to-lot consistency. See the instructions for more information on validation.

Target Name N-terminal pro-brain natriuretic peptide,NT-proBNP
Abbreviation NT-proBNP
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates
Detection Range 0.312 ng/mL-20 ng/mL
Sensitivity 0.216 ng/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Cardiovascular
Assay Principle quantitative
Measurement Sandwich
Precision

 

Intra-assay Precision (Precision within an assay): CV%

Three samples of known concentration were tested twenty times on one plate to assess.

Inter-assay Precision (Precision between assays):CV%

Three samples of known concentration were tested in twenty assays to assess.

 

Linearity

 

To assess the linearity of the assay, samples were spiked with high concentrations of humanNT-proBNPin various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.

 

Typical Data

 

These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.

 

   
Materials not provided
  • A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
  • An incubator can provide stable incubation conditions up to 37°C±5°C.
  • Centrifuge
  • Vortex
  • Squirt bottle, manifold dispenser, or automated microplate washer
  • Absorbent paper for blotting the microtiter plate
  • 50-300ul multi-channel micropipette
  • Pipette tips
  • Single-channel micropipette with different ranges
  • 100ml and 500ml graduated cylinders
  • Deionized or distilled water
  • Timer
  • Test tubes for dilution
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days