18 years of successful growth

Human Neural -Cadherin, N-Cad ELISA kit

Product Details

Target Name cadherin 2, type 1, N-cadherin (neuronal)
Alternative Names CADH2_HUMAN ELISA Kit; Cadherin 2 ELISA Kit; Cadherin 2 N cadherin neuronal ELISA Kit; Cadherin 2 type 1 ELISA Kit; Cadherin 2 type 1 N cadherin neuronal ELISA Kit; Cadherin 2; type 1; N-cadherin (neuronal) ELISA Kit; Cadherin-2 ELISA Kit; Cadherin2 ELISA Kit; Calcium dependent adhesion protein neuronal ELISA Kit; CD325 ELISA Kit; CD325 antigen ELISA Kit; CDH2 ELISA Kit; CDHN ELISA Kit; CDw325 ELISA Kit; CDw325 antigen ELISA Kit; N cadherin 1 ELISA Kit; N-cadherin ELISA Kit; NCAD ELISA Kit; Neural cadherin ELISA Kit; OTTHUMP00000066304 ELISA Kit; OTTHUMP00000067378 ELISA Kit
Abbreviation CDH2
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates
Detection Range 6.25 ng/mL-400 ng/mL
Sensitivity 1.56 ng/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Cancer
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human N-Cad in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 88  
Range % 80-100  
1:2 Average % 97  
Range % 91-104  
1:4 Average % 97  
Range % 92-108  
1:8 Average % 94  
Range % 85-98  
Recovery
The recovery of human N-Cad spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 95 89-105  
EDTA plasma (n=4) 97 90-110  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
             
             
             
             
             
             
             
             
             
             
             
             
             
ng/ml OD1 OD2 Average Corrected  
400 2.152 2.174 2.163 2.005  
200 1.832 1.824 1.828 1.670  
100 1.220 1.251 1.236 1.078  
50 0.926 0.974 0.950 0.792  
25 0.574 0.543 0.559 0.401  
12.5 0.406 0.426 0.416 0.258  
6.25 0.335 0.312 0.324 0.166  
0 0.152 0.164 0.158    
             
Storage Store at 2-8°C. Please refer to protocol.