18 years of successful growth

Human Neuronal Nitric Oxide Synthase (nNOS) ELISA Kit

Product Details

Target Name nitric oxide synthase 1 (neuronal)
Alternative Names 2310005C01Rik ELISA Kit; BNOS ELISA Kit; Constitutive NOS ELISA Kit; EC 1.14.13.39 ELISA Kit; IHPS 1 ELISA Kit; IHPS1 ELISA Kit; N-NOS ELISA Kit; NC-NOS ELISA Kit; neuronal Nitric Oxide Synthase ELISA Kit; Neuronal NOS ELISA Kit; Nitric oxide synthase ; neuronal; included ELISA Kit; Nitric oxide synthase 1 (neuronal) ELISA Kit; Nitric oxide synthase 1 ELISA Kit; Nitric oxide synthase; brain ELISA Kit; Nitric oxide synthase; penile neuronal; included ELISA Kit; NNOS ELISA Kit; NO ELISA Kit; NOS 1 ELISA Kit; NOS ELISA Kit; NOS type I ELISA Kit; NOS-I ELISA Kit; NOS1 ELISA Kit; NOS1_HUMAN ELISA Kit; Peptidyl-cysteine S-nitrosylase NOS1 ELISA Kit
Abbreviation NOS1
Species Homo sapiens (Human)
Sample Types serum, plasma, cell culture supernates
Detection Range 0.156 IU/mL-10 IU/mL
Sensitivity 0.039 IU/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Neuroscience
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human nNOS in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:5 Average % 87  
Range % 82-90  
1:10 Average % 105  
Range % 101-110  
1:20 Average % 83  
Range % 80-86  
1:40 Average % 97  
Range % 91-103  
Recovery
The recovery of human nNOS spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 89 85-93  
EDTA plasma (n=4) 100 95-105  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
IU/ml OD1 OD2 Average Corrected  
10 2.902 2.963 2.933 2.743  
5 2.313 2.365 2.339 2.149  
2.5 1.469 1.465 1.467 1.277  
1.25 0.878 0.822 0.850 0.660  
0.625 0.568 0.545 0.557 0.367  
0.312 0.407 0.435 0.421 0.231  
0.156 0.314 0.326 0.320 0.130  
0 0.192 0.187 0.190    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days
Download X-Ray Brochures