18 years of successful growth

Human paraoxonase,PON ELISA Kit

Product Details

Target Name paraoxonase 1
Alternative Names A esterase 1 ELISA Kit; A-esterase 1 ELISA Kit; Aromatic esterase 1 ELISA Kit; Arylesterase 1 ELISA Kit; Arylesterase B type ELISA Kit; ESA ELISA Kit; Esterase A ELISA Kit; K 45 ELISA Kit; K-45 ELISA Kit; MVCD5 ELISA Kit; Paraoxonase 1 ELISA Kit; Paraoxonase ELISA Kit; Paraoxonase B type ELISA Kit; Paraoxonase, plasma ELISA Kit; Paraoxonase1 ELISA Kit; PON 1 ELISA Kit; PON ELISA Kit; PON1 ELISA Kit; PON1_HUMAN ELISA Kit; Serum aryldiakylphosphatase ELISA Kit; Serum aryldialkylphosphatase 1 ELISA Kit; Serum paraoxonase/arylesterase 1 ELISA Kit
Abbreviation PON1
Species Homo sapiens (Human)
Sample Types serum, plasma, cell culture supernates, tissue homogenates
Detection Range 31.25 mIU/mL-2000 mIU/mL
Sensitivity 7.81 mIU/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Cardiovascular
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human PON in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:100 Average % 88  
Range % 80-92  
1:200 Average % 98  
Range % 91-105  
1:400 Average % 103  
Range % 92-110  
1:800 Average % 93  
Range % 86-98  
Recovery
The recovery of human PON spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 93 89-98  
EDTA plasma (n=4) 95 90-100  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
mIU/ml OD1 OD2 Average Corrected  
2000 2.655 2.603 2.629 2.521  
1000 2.292 2.248 2.283 2.175  
500 1.689 1.663 1.676 1.568  
250 1.025 0.989 1.007 0.899  
125 0.597 0.603 0.600 0.492  
62.5 0.409 0.398 0.404 0.296  
31.25 0.218 0.229 0.224 0.116  
0 0.109 0.107 0.108    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days