18 years of successful growth

Human proteinase 3(PR3) ELISA kit

Product Details

Target Name proteinase 3
Alternative Names ACPA ELISA Kit; AGP 7 ELISA Kit; AGP7 ELISA Kit; AGP7 serine proteinase ELISA Kit; Azurophil Granule Protein 7 ELISA Kit; C ANCA ELISA Kit; C ANCA antigen ELISA Kit; C-ANCA antigen ELISA Kit; CANCA ELISA Kit; EC 3.4.21.76 ELISA Kit; Leukocyte proteinase 3 ELISA Kit; MBN ELISA Kit; MBT ELISA Kit; MBT WEGENER AUTOANTIGEN ELISA Kit; Myeloblastin ELISA Kit; Neutrophil proteinase 4 ELISA Kit; NP 4 ELISA Kit; NP-4 ELISA Kit; NP4 ELISA Kit; P29 ELISA Kit; PR 3 ELISA Kit; PR-3 ELISA Kit; PR3 ELISA Kit; Proteinase 3 ELISA Kit; Proteinase3 ELISA Kit; PRTN 3 ELISA Kit; Prtn3 ELISA Kit; PRTN3_HUMAN ELISA Kit; Serine proteinase neutrophil Wegener granulomatosis autoantigen ELISA Kit; Serine proteinase; neutrophil ELISA Kit; Wegener autoantigen ELISA Kit; Wegener granulomatosis autoantigen ELISA Kit
Abbreviation PRTN3
Species Homo sapiens (Human)
Sample Types serum, tissue homogenates, plasma, urine
Detection Range 0.78 ng/mL-50 ng/mL
Sensitivity 0.195 ng/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Signal Transduction
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human PR3 in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 90  
Range % 86-95  
1:2 Average % 88  
Range % 81-93  
1:4 Average % 98  
Range % 93-102  
1:8 Average % 102  
Range % 98-106  
Recovery
The recovery of human PR3 spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 104 94-110  
EDTA plasma (n=4) 92 88-97  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
ng/ml OD1 OD2 Average Corrected  
50 2.002 2.050 2.026 1.934  
25 1.503 1.584 1.544 1.452  
12.5 1.014 1.101 1.058 0.966  
6.25 0.598 0.606 0.602 0.510  
3.12 0.384 0.387 0.386 0.294  
1.56 0.295 0.301 0.298 0.206  
0.78 0.197 0.189 0.193 0.101  
0 0.095 0.089 0.092    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days
Download X-Ray Brochures