18 years of successful growth

Human Stem Cell Factor Receptor,SCFR ELISA kit

Product Details

Target Name Stem Cell Factor Receptor,SCFR
Alternative Names C Kit ELISA Kit; c-Kit ELISA Kit; c-Kit Ligand ELISA Kit; CD117 ELISA Kit; Kit ELISA Kit; Kit Ligand ELISA Kit; KIT oncogene ELISA Kit; KIT proto oncogene receptor tyrosine kinase ELISA Kit; KIT_HUMAN ELISA Kit; Mast cell growth factor receptor ELISA Kit; Mast/stem cell growth factor receptor Kit ELISA Kit; MGF ELISA Kit; p145 c-kit ELISA Kit; PBT ELISA Kit; Piebald trait protein ELISA Kit; Proto oncogene c Kit ELISA Kit; Proto oncogene tyrosine protein kinase Kit ELISA Kit; Proto-oncogene c-Kit ELISA Kit; SCF Receptor ELISA Kit; SCFR ELISA Kit; soluble KIT variant 1 ELISA Kit; Steel Factor Receptor ELISA Kit; Stem cell factor receptor ELISA Kit; tyrosine protein kinase Kit ELISA Kit; Tyrosine-protein kinase Kit ELISA Kit; v kit Hardy Zuckerman 4 feline sarcoma viral oncogene homolog ELISA Kit; v kit Hardy Zuckerman 4 feline sarcoma viral oncogene like protein ELISA Kit; v-kit Hardy-Zuckerman 4 feline sarcoma viral oncogene homolog ELISA Kit
Abbreviation SCFR
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates
Detection Range 1.56 ng/mL-100 ng/mL
Sensitivity 0.39 ng/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Others
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human SCFR in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 93  
Range % 85-103  
1:2 Average % 89  
Range % 85-99  
1:4 Average % 93  
Range % 86-98  
1:8 Average % 92  
Range % 83-100  
Recovery
The recovery of human SCFR spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 93 86-101  
EDTA plasma (n=4) 97 91-105  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
ng/ml OD1 OD2 Average Corrected  
100 1.891 1.916 1.904 1.741  
50 1.349 1.397 1.373 1.210  
25 0.954 0.992 0.973 0.810  
12.5 0.632 0.654 0.643 0.480  
6.25 0.435 0.426 0.431 0.268  
3.12 0.318 0.307 0.313 0.150  
1.56 0.249 0.254 0.252 0.089  
0 0.161 0.165 0.163    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days