18 years of successful growth

Human tartrate-resistant acid phosphatase 5b,TRACP-5b ELISA Kit

Product Details

Target Name acid phosphatase 5, tartrate resistant
Alternative Names phosphatase ELISA Kit; Acid phosphatase 5 tartrate resistant ELISA Kit; Acid phosphatase 5; tartrate resistant ELISA Kit; ACP5 ELISA Kit; EC 3.1.3.2 ELISA Kit; MGC117378 ELISA Kit; PPA5_HUMAN ELISA Kit; serum band 5 tartrate-resistant acid phosphatase ELISA Kit; SPENCDI ELISA Kit; T5ap ELISA Kit; Tartrate resistant acid ATPase ELISA Kit; Tartrate resistant acid phosphatase type 5 ELISA Kit; Tartrate resistant acid phosphatase type 5 precursor ELISA Kit; Tartrate-resistant acid ATPase ELISA Kit; Tartrate-resistant acid phosphatase type 5 ELISA Kit; TR AP ELISA Kit; TR-AP ELISA Kit; TRACP 5 ELISA Kit; TRAP ELISA Kit; TrATPase ELISA Kit; Type 5 acid phosphatase ELISA Kit
Abbreviation ACP5
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates
Detection Range 0.312 mIU/mL-20 mIU/mL
Sensitivity 0.078 mIU/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Signal Transduction
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human TRACP-5b in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 88  
Range % 83-92  
1:2 Average % 99  
Range % 94-102  
1:4 Average % 105  
Range % 100-108  
1:8 Average % 95  
Range % 90-98  
Recovery
The recovery of human TRACP-5b spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 95 92-97  
EDTA plasma (n=4) 96 92-99  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
mIU/ml OD1 OD2 Average Corrected  
20 2.484 2.456 2.470 2.357  
10 1.918 1.876 1.897 1.784  
5 1.262 1.251 1.257 1.144  
2.5 0.666 0.715 0.691 0.578  
1.25 0.424 0.454 0.439 0.326  
0.625 0.312 0.329 0.321 0.208  
0.312 0.199 0.208 0.204 0.091  
0 0.111 0.115 0.113    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days