18 years of successful growth

Human Titin(TTN) ELISA kit

Product Details

Target Name titin
Alternative Names MPRM ELISA Kit; Cardiomyopathy dilated 1G (autosomal dominant) ELISA Kit; CMD1G ELISA Kit; CMH 9 ELISA Kit; CMH9 ELISA Kit; CMPD 4 ELISA Kit; CMPD4 ELISA Kit; Connectin ELISA Kit; DKFZp451N061 ELISA Kit; EOMFC ELISA Kit; FLJ26020 ELISA Kit; FLJ26409 ELISA Kit; FLJ32040 ELISA Kit; FLJ34413 ELISA Kit; FLJ39564 ELISA Kit; FLJ43066 ELISA Kit; HMERF ELISA Kit; LGMD2J ELISA Kit; MU RMS 40.14 ELISA Kit; MYLK5 ELISA Kit; Rhabdomyosarcoma antigen ELISA Kit; Rhabdomyosarcoma antigen MU RMS 40.14 ELISA Kit; Rhabdomyosarcoma antigen MU-RMS-40.14 ELISA Kit; Titin ELISA Kit; TITIN_HUMAN ELISA Kit; TMD ELISA Kit; TTN ELISA Kit
Abbreviation TTN
Species Homo sapiens (Human)
Sample Types serum, plasma, tissue homogenates, cell lysates
Detection Range 23.5 pg/mL-1500 pg/mL
Sensitivity 5.8 pg/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Signal Transduction
Assay Principle quantitative
Measurement Sandwich
Precision
Intra-assay Precision (Precision within an assay): CV%   
Three samples of known concentration were tested twenty times on one plate to assess.  
Inter-assay Precision (Precision between assays): CV%   
Three samples of known concentration were tested in twenty assays to assess.    
             
Linearity
To assess the linearity of the assay, samples were spiked with high concentrations of human TTN in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay.
  Sample Serum(n=4)  
1:1 Average % 98  
Range % 94-104  
1:2 Average % 96  
Range % 91-101  
1:4 Average % 93  
Range % 87-99  
1:8 Average % 92  
Range % 84-98  
Recovery
The recovery of human TTN spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section.
Sample Type Average % Recovery Range  
Serum (n=5) 96 92-100  
EDTA plasma (n=4) 98 90-106  
             
             
Typical Data
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.
pg/ml OD1 OD2 Average Corrected  
1500 2.195 2.095 2.145 2.014  
750 1.594 1.494 1.544 1.413  
375 0.932 0.892 0.912 0.781  
187.5 0.506 0.486 0.496 0.365  
94 0.352 0.342 0.347 0.216  
47 0.229 0.219 0.224 0.093  
23.5 0.168 0.162 0.165 0.034  
0 0.131 0.130 0.131    
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 7-14 working days