Human Vascular Endothelial cell Growth Factor(VEGF) ELISA KIT
Product Details
Target Name |
vascular endothelial growth factor A |
Alternative Names |
glioma-derived endothelial cell mitogen ELISA Kit; MGC70609 ELISA Kit; MVCD1 ELISA Kit; Vascular endothelial growth factor A ELISA Kit; Vascular Endothelial Growth Factor ELISA Kit; Vascular permeability factor ELISA Kit; VEGF ELISA Kit; VEGF-A ELISA Kit; VEGF165 ELISA Kit; Vegfa ELISA Kit; VEGFA_HUMAN ELISA Kit; VPF ELISA Kit |
Abbreviation |
VEGFA |
Species |
Homo sapiens (Human) |
Sample Types |
serum, plasma, cell culture supernates, tissue homogenates, cell lysates, urine |
Detection Range |
31.25 pg/mL-2000 pg/mL |
Sensitivity |
25.297 pg/mL |
Assay Time |
1-5h |
Sample Volume |
50-100ul |
Detection Wavelength |
450 nm |
Research Area |
Cancer |
Assay Principle |
quantitative |
Measurement |
Sandwich |
Precision |
Intra-assay Precision (Precision within an assay): CV% |
Three samples of known concentration were tested twenty times on one plate to assess. |
|
Inter-assay Precision (Precision between assays): CV% |
Three samples of known concentration were tested in twenty assays to assess. |
|
|
|
|
|
|
|
|
|
|
Linearity |
To assess the linearity of the assay, samples were spiked with high concentrations of human VEGF in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
|
Sample |
Serum(n=4) |
|
1:1 |
Average % |
98 |
|
Range % |
94-106 |
|
1:2 |
Average % |
93 |
|
Range % |
86-97 |
|
1:4 |
Average % |
87 |
|
Range % |
82-93 |
|
1:8 |
Average % |
96 |
|
Range % |
91-105 |
|
|
Recovery |
The recovery of human VEGF spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
Sample Type |
Average % Recovery |
Range |
|
Serum (n=5) |
89 |
85-93 |
|
EDTA plasma (n=4) |
92 |
90-96 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Typical Data |
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
pg/ml |
OD1 |
OD2 |
Average |
Corrected |
|
2000 |
2.651 |
2.751 |
2.701 |
2.547 |
|
1000 |
1.729 |
1.829 |
1.779 |
1.625 |
|
500 |
1.067 |
1.087 |
1.077 |
0.923 |
|
250 |
0.579 |
0.589 |
0.584 |
0.430 |
|
125 |
0.372 |
0.382 |
0.377 |
0.223 |
|
62.5 |
0.255 |
0.265 |
0.260 |
0.106 |
|
31.25 |
0.207 |
0.209 |
0.208 |
0.054 |
|
0 |
0.153 |
0.154 |
0.154 |
|
|
|
|
Storage |
Store at 2-8°C. Please refer to protocol. |
Lead Time |
3-5 working days |