Rat eosinophil cationic protein,ECP ELISA Kit
Product Details
| Target Name |
ribonuclease, RNase A family, 3 (eosinophil cationic protein) |
| Alternative Names |
Rnase3 ELISA Kit; Ear11 ELISA Kit; Rns3 ELISA Kit; Eosinophil cationic protein ELISA Kit; ECP ELISA Kit; EC 3.1.27.- ELISA Kit; Eosinophil secondary granule ribonuclease 11 ELISA Kit; EAR-11 ELISA Kit; Ribonuclease 3 ELISA Kit; RNase 3 ELISA Kit |
| Abbreviation |
RNASE3 |
| Species |
Rattus norvegicus (Rat) |
| Sample Types |
serum, plasma, tissue homogenates |
| Detection Range |
62.5 pg/mL-4000 pg/mL |
| Sensitivity |
15.6 pg/mL |
| Assay Time |
1-5h |
| Sample Volume |
50-100ul |
| Detection Wavelength |
450 nm |
| Research Area |
Others |
| Assay Principle |
quantitative |
| Measurement |
Sandwich |
| Precision |
| Intra-assay Precision (Precision within an assay): CV% |
|
|
|
|
| Three samples of known concentration were tested twenty times on one plate to assess. |
|
|
| Inter-assay Precision (Precision between assays): CV% |
|
|
|
|
| Three samples of known concentration were tested in twenty assays to assess. |
|
|
|
| |
|
|
|
|
|
|
|
|
| Linearity |
| To assess the linearity of the assay, samples were spiked with high concentrations of rat ECP in various matrices and diluted with the Sample Diluent to produce samples with values within the dynamic range of the assay. |
|
| |
Sample |
Serum(n=4) |
|
|
| 1:1 |
Average % |
95 |
|
|
| Range % |
90-100 |
|
|
| 1:2 |
Average % |
101 |
|
|
| Range % |
96-107 |
|
|
| 1:4 |
Average % |
92 |
|
|
| Range % |
88-96 |
|
|
| 1:8 |
Average % |
89 |
|
|
| Range % |
84-93 |
|
|
|
| Recovery |
| The recovery of rat ECP spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay as directed in the Sample Preparation section. |
|
| |
| Sample Type |
Average % Recovery |
Range |
|
|
| Serum (n=5) |
94 |
90-98 |
|
|
| EDTA plasma (n=4) |
87 |
82-91 |
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Typical Data |
| These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. |
|
| |
| pg/ml |
OD1 |
OD2 |
Average |
Corrected |
|
|
| 4000 |
2.651 |
2.529 |
2.590 |
2.382 |
|
|
| 2000 |
2.004 |
1.903 |
1.954 |
1.746 |
|
|
| 1000 |
1.310 |
1.385 |
1.348 |
1.140 |
|
|
| 500 |
0.829 |
0.851 |
0.840 |
0.632 |
|
|
| 250 |
0.492 |
0.476 |
0.484 |
0.276 |
|
|
| 125 |
0.347 |
0.337 |
0.342 |
0.134 |
|
|
| 62.5 |
0.285 |
0.294 |
0.290 |
0.082 |
|
|
| 0 |
0.203 |
0.212 |
0.208 |
|
|
|
|
|
| Storage |
Store at 2-8°C. Please refer to protocol. |
| Lead Time |