18 years of successful growth

Rat Tri-iodothyronine,T3 ELISA Kit

Product Details

Description
The sensitive quantitative measurement of total rat tr-iodothyronine (T3) in serum, plasma, cell culture supernates, or tissue homogenates is easily performed with this 96 well strip format ELISA kit. This assay employs the competitive inhibition enzyme immunoassay technique, in which  T3 in the standards or the samples competes with biotin-conjugated T3 for binding to the pre-coated T3 antibody. And the color elicited by HRP-TMB chromogenic reaction develops in opposite to the amount of T3 in the sample. The color development is stopped upon the addition of the stop solution and the intensity of the color is measured by a microplate reader at 450 nm. This Human T3 ELISA Kit has high sensitivity and excellent specificity for the detection of T3. And it also has been validated with precision low than 15%, good linearity, high recovery, and lot-to-lot consistency. Refer to the product instructions for more details. T3 is a thyroid hormone that almost affects all physiological proces...Read more
Target Name Tri-iodothyronine,T3
Abbreviation T3
Species Rattus norvegicus (Rat)
Sample Types serum, plasma, cell culture supernates, tissue homogenates
Detection Range 0.5 ng/mL-8 ng/mL
Sensitivity 0.5 ng/mL
Assay Time 1-5h
Sample Volume 50-100ul
Detection Wavelength 450 nm
Research Area Signal Transduction
Assay Principle quantitative
Measurement Competitive
Precision

Intra-assay Precision (Precision within an assay): CV%

 

Three samples of known concentration were tested twenty times on one plate to assess.

 

Inter-assay Precision (Precision between assays): CV%

 

Three samples of known concentration were tested in twenty assays to assess.

  

Typical Data

 These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.

 

Materials provided
  • A 96-well Assay plate --The 96-well plate has been pre-coated with an anti-human Ts antibody.
  • Standard(10 x concentrate) (6 x 1 ml) --Dilute the standard at dilution series, read the OD values, and then draw a standard curve.
  • Biotin-conjugated T3 (1 x  6 ml)
  • HRP-avidin (1 x 6 ml) --Catalyze the TMB, eliciting a chromogenic reaction.
  • Wash Buffer (20x concentrate) (1 x 15 ml) --Wash away unbound or free substances.
  • Substrate A (1x 7 ml) --Mix with Substrate B.
Materials not provided
  • A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 600 nm - 630 nm.
  • An incubator that can provide stable incubation conditions up to 37°C±5°
  • Centrifuge
  • Vortex
  • Squirt bottle, manifold dispenser, or automated microplate washer
  • Absorbent paper for blotting the microtiter plate
Storage Store at 2-8°C. Please refer to protocol.
Lead Time 3-5 working days